Line 10: Line 10:
   * [[ http://www.ixxat.com/can_repeater_en.html | CAN-Repeater]] : ISO 11898-2 CAN Repeater; can be equipped with a low-speed bus interface (ISO 11898-3), allowing the operation as high/low-speed converter. Its galvanic isolation isolates both CAN segments from each other as well as from the power supply.   * [[ http://www.ixxat.com/can_repeater_en.html | CAN-Repeater]] : ISO 11898-2 CAN Repeater; can be equipped with a low-speed bus interface (ISO 11898-3), allowing the operation as high/low-speed converter. Its galvanic isolation isolates both CAN segments from each other as well as from the power supply.
   * [[ http://www.ixxat.com/can_cr200_en.html | CAN-CR200]] Modular ISO 11898-2 CAN Repeater;  Several CAN-CR200 can be connected to a CAN-hub via the integrated backbone bus; automatic recognition and separation of a defective segment from the rest of the network, after elimination of defect, segment is switched into the network again; galvanic isolation between CAN segments as well as power supply.   * [[ http://www.ixxat.com/can_cr200_en.html | CAN-CR200]] Modular ISO 11898-2 CAN Repeater;  Several CAN-CR200 can be connected to a CAN-hub via the integrated backbone bus; automatic recognition and separation of a defective segment from the rest of the network, after elimination of defect, segment is switched into the network again; galvanic isolation between CAN segments as well as power supply.
-  * [[ http://www.ixxat.de/can_cr220_en,21892,5873.html | IXXAT CAN-CR220]] : CAN interface according ISO/IS 11898-2 with CAN choke. Two Sub-D9 connectors. CAN 1, CAN 2 and power supply are galvanic isolated against each other. Galvanic isolation 4 kV/1 second, 2.5 kV/60 seconds. CAN termination resistors are integrated (can be disabled).Delay 200 ns. +  * [[ http://www.ixxat.de/can_cr220_en,21892,5873.html | CAN-CR220]] : CAN interface according ISO/IS 11898-2 with CAN choke. Two Sub-D9 connectors. CAN 1, CAN 2 and power supply are galvanic isolated against each other. Galvanic isolation 4 kV/1 second, 2.5 kV/60 seconds. CAN termination resistors are integrated (can be disabled).Delay 200 ns. 
   * [[http://www.ixxat.com/can_cr210_en.html | CAN-CR210/FO ]] stackable converter from ISO 11898-2 to fiber optic cable; CAN termination resistors integrated (switchable); integrated backbone bus; automatic recognition and separation of defective segment (see CAN-CR220)   * [[http://www.ixxat.com/can_cr210_en.html | CAN-CR210/FO ]] stackable converter from ISO 11898-2 to fiber optic cable; CAN termination resistors integrated (switchable); integrated backbone bus; automatic recognition and separation of defective segment (see CAN-CR220)
   * [[http://www.ixxat.com/fo-repeater_en.html | FO-Repeater ]] converter from ISO 11898 to fiber optic cable; CAN termination resistors integrated (switchable); automatic recognition and separation of defective segment (see CAN-CR220)   * [[http://www.ixxat.com/fo-repeater_en.html | FO-Repeater ]] converter from ISO 11898 to fiber optic cable; CAN termination resistors integrated (switchable); automatic recognition and separation of defective segment (see CAN-CR220)
Line 18: Line 18:
 CAN bridges allow the coupling of two CAN networks, including networks with different bit rates. Unlike a CAN repeater, which only translates the electric signals, CAN messages are received completely by the CAN bridge and then sent to the other CAN network in line with existing filter and conversion rules. With these mechanisms, the bus load can be reduced in the individual networks by only sending messages which are of interest to the other network. CAN bridges allow the coupling of two CAN networks, including networks with different bit rates. Unlike a CAN repeater, which only translates the electric signals, CAN messages are received completely by the CAN bridge and then sent to the other CAN network in line with existing filter and conversion rules. With these mechanisms, the bus load can be reduced in the individual networks by only sending messages which are of interest to the other network.
  
-* [[ http://www.ixxat.com/index_en.html | IXXAT ]] [[http://www.ixxat.com/can_bridge_en.html | CANbridge]] Configurable CAN/CAN Bridge; available in Industrial Version (2x ISO 11898-2, as an option galvanic isolated) and Automotive Version (1x ISO 11898-2, galvanic isolated, 1x ISO 11898-3)+* [[ http://www.ixxat.com/index_en.html | IXXAT ]] [[http://www.ixxat.com/can_bridge_en.html | CANbridge]] Configurable CAN/CAN Bridge; available in Industrial Version (2x ISO 11898-2, as an option galvanic isolated; DIN rail or robust metal housing) and Automotive Version (1x ISO 11898-2, galvanic isolated, 1x ISO 11898-3; robust metal housing)
  

QR Code