   * [[ http://www.ixxat.com/can_repeater_en.html | CAN-Repeater]] : ISO 11898-2 CAN Repeater; can be equipped with a low-speed bus interface (ISO 11898-3), allowing the operation as high/low-speed converter. Its galvanic isolation isolates both CAN segments from each other as well as from the power supply.   * [[ http://www.ixxat.com/can_repeater_en.html | CAN-Repeater]] : ISO 11898-2 CAN Repeater; can be equipped with a low-speed bus interface (ISO 11898-3), allowing the operation as high/low-speed converter. Its galvanic isolation isolates both CAN segments from each other as well as from the power supply.
   * [[ http://www.ixxat.com/can_cr200_en.html | CAN-CR200]] Modular ISO 11898-2 CAN Repeater;  Several CAN-CR200 can be connected to a CAN-hub via the integrated backbone bus; automatic recognition and separation of a defective segment from the rest of the network, after elimination of defect, segment is switched into the network again; galvanic isolation between CAN segments as well as power supply.   * [[ http://www.ixxat.com/can_cr200_en.html | CAN-CR200]] Modular ISO 11898-2 CAN Repeater;  Several CAN-CR200 can be connected to a CAN-hub via the integrated backbone bus; automatic recognition and separation of a defective segment from the rest of the network, after elimination of defect, segment is switched into the network again; galvanic isolation between CAN segments as well as power supply.
-  * [[ http://www.ixxat.de/can_cr220_en,21892,5873.html | IXXAT CAN-CR220]] : CAN interface according ISO/IS 11898-2 with CAN choke. Two Sub-D9 connectors. CAN 1, CAN 2 and power supply are galvanic isolated against each other. Galvanic isolation 4 kV/1 second, 2.5 kV/60 seconds. CAN termination resistors are integrated (can be disabled).Delay 200 ns. +  * [[ http://www.ixxat.de/can_cr220_en,21892,5873.html | CAN-CR220]] : CAN interface according ISO/IS 11898-2 with CAN choke. Two Sub-D9 connectors. CAN 1, CAN 2 and power supply are galvanic isolated against each other. Galvanic isolation 4 kV/1 second, 2.5 kV/60 seconds. CAN termination resistors are integrated (can be disabled).Delay 200 ns. 
   * [[http://www.ixxat.com/can_cr210_en.html | CAN-CR210/FO ]] stackable converter from ISO 11898-2 to fiber optic cable; CAN termination resistors integrated (switchable); integrated backbone bus; automatic recognition and separation of defective segment (see CAN-CR220)   * [[http://www.ixxat.com/can_cr210_en.html | CAN-CR210/FO ]] stackable converter from ISO 11898-2 to fiber optic cable; CAN termination resistors integrated (switchable); integrated backbone bus; automatic recognition and separation of defective segment (see CAN-CR220)
   * [[http://www.ixxat.com/fo-repeater_en.html | FO-Repeater ]] converter from ISO 11898 to fiber optic cable; CAN termination resistors integrated (switchable); automatic recognition and separation of defective segment (see CAN-CR220)   * [[http://www.ixxat.com/fo-repeater_en.html | FO-Repeater ]] converter from ISO 11898 to fiber optic cable; CAN termination resistors integrated (switchable); automatic recognition and separation of defective segment (see CAN-CR220)