- | Why is my CAN not working ? Here are some Problem Solving Questions | ||
- | This page should help you to find out why your network is not working by providing questions. Answering these questions should help to find out what is possibly going wrong. | ||
- | * Are there two 120 Ohm resistors across the bus at each end to terminate the network drivers? See CanCabling and DeviceNetCable | ||
- | |||
- | * Is there at least one other node on the bus? | ||
- | |||
- | * Are both CAN tranceivers (when there are only 2 nodes) fault tolerant? | ||
- | |||
- | * Are all the nodes CAN-A or are there CAN-B compliant devices? | ||
- | |||
- | * Are the grounds between nodes connected together? | ||
- | |||
- | * Are you using a Commercial Off The Shelf (COTS) dongle to listen in on the messages. In other words: "can you trust at least one member at the bus?". | ||
- | |||